![]() | TNT 12000 X-Ray Test Device. | ![]() |
![]() |
Technical DataThe TNT 12000 X-Ray Test Device is the newest and most versatile instrument available for measuring key x-ray imaging parameters. It sets up in seconds and measures kVp, dose, dose rate, time, and half value layer (HVL) in a single exposure. A totally-wireless ZigBee® interface enables quick and easy setup and the wireless detector can be used with the companion wireless display or a laptop computer. X-ray imaging QA, calibration, and maintenance in today’s demanding digital environment require very high productivity and compliance with local and regional regulations. The TNT 12000 delivers high productivity through 100 % wireless connectivity to either a display, which instantly responds with all values in a single exposure, or a laptop, where measured values are displayed and categorized in organized templates. Instant HVL with just a single exposure further enhances productivity. Key features Product positioning The TNT 12000 takes over where other technology leaves off. Featuring all-in-one-exposure measurements and ZigBee wireless communication combined with the rugged, reliable, and accurate design that is a Fluke trademark, the TNT 12000 is truly a new breed of noninvasive x-ray test tool. TNT 12000 is ideal for use by OEM factory and field service engineers, independent service organizations, physicists, biomedical and clinical engineers, and local and regional field inspectors of x-ray imaging equipment. Its small, lightweight design enhances portability and 100 % wireless operation ensures setup can be accomplished in seconds. Because the TNT 12000 measures all parameters with every exposure, there is no need for complicated menu selection, further enhancing user productivity. TNT 12000 always |
| defaults to the last use when powered on, so when used often for repetitive procedures it is truly a one-button
(power-on) solution. The TNT 12000 has the expanded functionality needed for modern applications and can be managed with
minimum keystrokes. Users can identify and select custom measurement protocols and save them for future use. Full test
automation and documentation software is available for TNT 12000, creating the advantage of accurate, repeatable
testing processes. Ansur Test Automation Software is only available from Fluke Biomedical. Primary end benefit Productivity and accuracy are central goals when performing any maintenance or QA process on diagnostic imaging equipment because image system uptime is critical to patient care objectives. TNT 12000 is small, portable, and wireless. It is easily transported to the imaging room, set up in seconds, and all results are instantly available on the hand-held display or on the user’s laptop. The latter application places measured values into templates that are standard with the Excel software provided with TNT 12000. Because the TNT 12000 Excel package is a spreadsheet, users can customize their templates and create their own reports to send to others. Accuracy, reproducibility, and reliability are also critically important and Fluke Biomedical is the industry standard customers count on to deliver uncompromised performance. Technical specifications Physical specifications Display: 320 × 240 Color LCD Size (WxDxH) Display: 15.2 cm x 11.4 cm x 4.45 cm (6 in × 4.5 in × 1.75 in) Detector: 15.2 cm x 11.4 cm x 4.45 cm (6 in × 4.5 in × 1.75 in) Weight Display: 0.422 kg (0.93 lb) Detector: 0.68 kg (1.5 lb) Electrical specifications Battery Battery type: Lithium-ion, 3.7 V, 4000 mAh Battery charge time: Approx. 5 hr Battery discharge time: Approx. 8 hr Battery cutoff voltage: 2.75 V AC adapter | ![]() |
![]() | Input voltage: 100 V ac to 240 V ac Input frequency: 50/60 Hz Input current: 0.5 A (rms) Output voltage: 6 V dc Environmental specifications Operating temperature: 0 °C to 35 °C (32 ºF to 95 ºF) Storage temperature: -35 °C to 50 °C (-31 ºF to 122 ºF) Operating humidity: 20 % to 80 % RH (non-condensing) kVp measurements Units: kVp Average (average of peaks during a specified interval) kVp Max: (highest peak during a specified interval) PPV (peak practical voltage) Ranges Radio/Fluoro modes: 40 kV to 150 kV Mammo modes: Mo/Mo: 22 kV to 35 kV (standard calibration) Rh/Rh: 25 kV to 49 kV (optional calibration) Mo/Rh: 22 kV to 40 kV (optional calibration) Mo/Al: 22 kV to 49 kV (optional calibration) Rh/Al: 25 kV to 49 kV (optional calibration) W/Rh: (optional calibration) W/Ag: (optional calibration) Resolution: 0.1 kV Accuracy: (including calibration uncertainty) Radio/Fluoro modes: ± 5 % Mammo modes: ± 5 % Reproducibility: ± 1 % (std of 5 readings) Filtration correction range Radio/Fluoro modes: 1 mm Al to 10 mm Al or equivalent Mammo mode: 0 mm Al to 0.4 mm Al added filtration |
| Dose/Exposure measurements Units: Roentgens, grays Range: 10 mR to 999 R, 0.1 mGy to 999 Gy Resolution: 1 μR 0.01 μGy Accuracy: ± 5 % (including calibration uncertainty) Reproducibility: ± 1 % (std of five readings) Filtration correction range Radio/Fluoro modes: 1 mm Al to 10 mm Al or equivalent Mammo mode: 0 mm Al to 0.4 mm Al added filtration kV correction ranges Radio/Fluoro modes: 40 kV to 150 kV Mammo mode: Mo/Mo: 22 kV to 35 kV Dose/Exposure rate measurements Units: Roentgens or grays per hour, minute, second, pulse Range 50 mR to 19.9 R/s 0.5 mGy to 199 mGy/s 2 μR/pulse to 333 mR/pulse (@ 60 PPS) 0.02 μGy/pulse to 3.33 mGy/ pulse (@ 60 PPS) Resolution 1 μR/s 0.01 μGy/s 0.02 μR/pulse (@ 60 PPS) 0.2 nGy/pulse (@ 60 PPS) Accuracy ± 5 % (including calibration uncertainty) Filtration correction range Radio/Fluoro modes: 1 mm Al to 10 mm Al or equivalent Mammo mode: 0 mm Al to 0.4 mm Al added filtration kV correction range Radio/Fluoro modes: 40 kV to 150 kV Mammo mode: Mo/Mo: 22 kV to 35 kV | ![]() |
![]() | Exposure time—radiographic modes Units: Milliseconds, pulses Range: Milliseconds: 10 ms to 999 ms; Pulses: 1 pulse to 999 pulses Resolution: Milliseconds: 0.1 ms; Pulses: 1 pulse Accuracy: Milliseconds: 1 % or 0.5 ms; Pulses: ± 1 pulse Reproducibility: Milliseconds: 1 % or 0.5 ms; Pulses: ± 1 pulse Elapsed time—fluoro modes Range: 10 sec to 999 sec Resolution: 0.1 second Accuracy: 1 % or 0.5 sec Average pulse rate—pulsed fluoro Range: 1 pps to 999 pps (pulses per second) Resolution:1 pps Accuracy: 1 pps Average pulse width— pulsed fluoro Range: 10 ms to 999 ms Resolution: 0.1 ms Accuracy: 1 % or 0.5 ms HVL Range Radio/Fluoro modes: 1.2 mm Al to 10 mm Al (equivalent) Mammo mode: 0.2 mm Al to 0.4 mm Al (equivalent) Resolution Radio/Fluoro modes: 0.1 mm Al (equivalent) Mammo mode: 0.01 mm Al (equivalent) Accuracy Radio/Fluoro modes: ± 10 % or 0.2 mm Al (equivalent) Mammo mode: ± 5 % or 0.05 mm Al (equivalent) |
|
|
![]() |
![]() |