Oprax Medical Inc.

4000M+ X-Ray Test Device.


Fluke Biomedical, Inc.
  • Measures kVp maximum, kVp average, kVp effective, dose and time in one exposure
  • Compact, lightweight design
  • Displays R or Gy
  • External ion chambers for Mammo, CT, image intensifier and phototiming measurements
  • Automatic exposure reset for hands off operation
  • Rechargeable Ni-Cd batteries provide more than six hours of continuous service
  • RS-232 computer interface
  • Storage scope output for real-time waveform display
  • Reversible display for fluoro measurements

  • Introduction
    The Victoreen® X-Ray Test Device, Model 4000M+ does it all. Simply place the instrument in the x-ray beam, make one exposure, and it serially displays kVp Maximum, kVp Average, kVp Effective, dose, and time. The Model 4000M+ then automatically resets for the next exposure. A CsI photodiode pair provide the kVp measurements through five user-selectable filter pairs. This ensures optimum accuracy over the entire diagnostic range with minimum filtration dependence. Exposure measurements are made with a parallel plate ionization chamber located above the filter wheel. Exposure time is measured with quartz crystal accuracy. Plus, a variety of external ion chambers may be connected for even greater flexibility.

    Specifications

    Kilovoltage Accuracy: 1 kV Mo/Mo (22 to 35 kVp), (Mammo generators w/30 μ Mo)
    Range: W/Al Tubes: 27 to 155 kVp, Mo/Mo Tubes: 21 to 50 kVp


    Time
    Measured during entire exposure at 90% rise/fall of waveform
    Accuracy: Within 2% or 2 ms, whichever is greater
    Range: 1 ms to 10 seconds

    Exposure
    Measure during entire exposure; kvp corrected
    Accuracy: ± 5%
    Range: 10 mR to 10 R

    Fluoroscopic rate
    Measured over one second intervals during fluoro exposure
    Accuracy: ± 5%
    Range: 0.5 to 200 R/min

    Detectors
    kV CsI/photodiode pair measures x-ray transmission through differential attenuators
    Time Computed from kV waveform stored in memory against quartz crystal time base
    Exposure Parallel plate ionization chamber
    Volume 36 cm³
    Window 38 mg/cm², 18.9 cm² polycarbonate
    Calibration Reference to a NIST traceable voltage divider and a calibrated exposure monitor during irradiation

    Physical


    Display 16 character dot-matrix LCD

    Controls Model 4000+ has five rocker switches
    - On/Off: Power switch
    - Radio/Fluoro: Select radiographic or fluoro operation
    - High/Low: Select for sensitivity
    - Roll: Roll thru data
    - Exposure/All: Select exposure only for external ion chamber
    - Mo/Mo or W/Al: Select anode/filter of x-ray tube

    Connectors
    - Power 9 VDC, 500 mA
    - Scope BNC for oscilloscope connection
    - RS-232 DB-9 connector configured as DCE. BNC and banana plug for external Ion chamber

    Power requirements 9 VDC 500 mA external supply. Rechargeable internal Ni-Cd batteries supply more than six hours of continuous service with overnight charge
    Dimensions 8.5 (w) x 9 (d) x 3 in (h) (21.5 x 23 x 7.6 cm)
    Weight Approximately 3.5 lb (1.59 kg)
    HVL set Aluminum filters: 2.3, 1.0, and 0.3 mm

    Optional Accessories
    4000 Toolkit for Excel (Model 4000EXL)
    Ultra-High Purity HVL Attenuators (Model 07-434): for mammo, set of 6
    Carrying Case (Model 4000-69)


    Stock #
    Description
    Your Price
    4000M+
    X-Ray Test Device
    $5,994.39
    4000-69
    Carrying Case for the 4000M+ Meter.
    $643.16
    07-434
    Ultra-High Purity HVL Attenuators for Mammo (Set of 6)
    $160.81
    190004
    RS-232 Cable 25Ft (7.6 m)m 9 pin to 9 Pin
    $115.14
    4000EXL
    4000 Toolkit Software for Excel
    $838.73
    14-301
    AC Adapter for USA/Japan (110VAC to 9VDC/500mA)
    $55.17
    14-399
    AC Adapter for Europe (230VAC to 9VDC /500mA)
    $44.29
    14-415
    AC Adapter for the UK & Portions of Australia (230VAC to 9VDC /500mA)
    $119.53
    14-416
    AC Adapter for the Portions of Australia (230VAC to 9VDC /500mA)
    $37.27